CircuitPlain
CircuitPlain is a straightforward reference for residential electrical DIY questions: breaker and panel comparisons, National Electrical Code (NEC) charts, box-fill math, and step-by-step troubleshooting. Every guide checks specs against published NEC editions and manufacturer installation manuals.
Browse by Topic
- Outlets & SwitchesGFCI vs AFCI rules, 3-way switch wiring, half-hot receptacles, and dead outlet troubleshooting.
- Breakers & PanelsSquare D Homeline vs QO comparisons, tripping breaker diagnostics, and panel compatibility.
- Wiring & Boxes14/2 vs 12/2 Romex NM-B rules, NEC 314.16 box fill calculations, splices, and conductors.
- Lighting & FixturesLED flicker troubleshooting, TRIAC vs ELV dimmers, neutral requirements, and driver checks.
- Generators & TransferGenerator interlock kits vs manual transfer switches, UL 67 vs UL 1008, and bonded neutrals.
- Codes & ChartsNEC Table 310.16 wire gauge vs ampacity charts, 240.4(D) limits, and reference tables.
Start Here
- GFCI vs AFCI: Differences, NEC Rules, and Where Each Goes — GFCI stops ground faults to prevent electrocution; AFCI stops arcing faults to prevent electrical fires.
- Square D Homeline vs QO: Breaker and Panel Differences — QO uses tin-plated copper bus bars and 3/4-inch Visi-Trip breakers with a lifetime warranty; Homeline uses plated aluminum bus bars and 1-inch breakers with a 10-year panel warranty.
- How to Wire a 3-Way Switch (Line, Load, and Traveler Guide) — Find the darker Common screw first—it gets either the hot feed or the wire to the light—while the two brass screws get the travelers.
- Wire Gauge vs Amp Chart for Residential Wiring (AWG to Breaker Size) — Copper NM-B (Romex) uses the 60°C column of NEC Table 310.16: 14 AWG = 15A, 12 AWG = 20A, 10 AWG = 30A, 8 AWG = 40A, 6 AWG = 55A, and 4 AWG = 70A.
- Electrical Box Fill Calculation (NEC 314.16 Chart & Examples) — Add up cubic-inch allowances for every conductor, internal clamp, device yoke (2x), and entering ground group, then pick a box equal to or larger than the total.
- Generator Interlock vs Transfer Switch: Which Backup Setup Fits Your Home? — An OEM interlock kit lets you power any circuit in your main panel cheaply by turning breakers on and off; a UL 1008 transfer switch isolates fixed circuits in its own enclosure.
All Guides
- GFCI vs AFCI: Differences, NEC Rules, and Where Each Goes
- Square D Homeline vs QO: Breaker and Panel Differences
- How to Wire a 3-Way Switch (Line, Load, and Traveler Guide)
- Wire Gauge vs Amp Chart for Residential Wiring (AWG to Breaker Size)
- Electrical Box Fill Calculation (NEC 314.16 Chart & Examples)
- Generator Interlock vs Transfer Switch: Which Backup Setup Fits Your Home?
- Outlet Has No Power but Breaker Isn't Tripped: 7 Causes & Checks
- Why Does My Circuit Breaker Keep Tripping? (Overload, Short, or Ground Fault)
- 14/2 vs 12/2 Romex (NM-B): Ampacity, Breaker Size, and When to Use Each
- Why Are My LED Lights Flickering? (Dimmer, Loose Neutral, or Voltage Drop)